Ceramic Capacitor DC Bias Effects & Measurement - Phil's Lab #152
        Basics of DC bias effects and derating of multi-layer ceramic capacitors (MLCC). Acquiring impedance vs frequency curves for DC-biased ceramic capacitors via the two-port shunt-through measurement technique.
    
    
            Chapters:
        
        - 00:00Intro
 - 02:00Interactive Designs
 - 02:28MLCC Basics
 - 04:52Derating Basics
 - 06:41Issues with Derating
 - 08:23Mitigation
 - 10:272-Port Shunt-Thru Measurement
 - 12:01DC Block & Bias Injector
 - 14:30Test Board
 - 15:28Measurement Set-Up
 - 16:50Bode Analyzer Software Set-Up
 - 18:36Test Capacitor
 - 19:270V DC Bias
 - 20:524V DC Bias
 - 23:1212V DC Bias
 - 25:06Outro
 